Availability: | |
---|---|
Model | ZYB1-63A |
Rated voltage | 220VAC 50Hz. |
Rated current | 1A-63A adjustable (default 40A) |
Overvoltage action cut-off value | 240V-300VAC can be set (default 270VAC) |
Overvoltage action cut-off value | 140V-200VAC can be set (default 170VAC) |
Overcurrent action cut-off value | 63A: 1A-63A can be set (default 40A) / 40A: 1 A-40A can be set |
Transmission delay time after power-on and power-off | 5-300S adjustable (default 5S) |
Boot delay time | 1-300S adjustable (default 5S) |
Reset delay time after overcurrent protection | 30-300s adjustable (default 30s) |
Product overcurrent delay time 6s (overcurrent time greater than this time will be confirmed as overcurrent and provide protection) | |
Own power consumption | less than or equal to 2W |
Electrical machinery life | greater than or equal to 100,000 times |
12 Product dimensions | 66*37*86mm |
Usge:
The multifunctional self-resetting dual display protector integrates over-voltage protection, under-voltage protection, over-current protection and integrated intelligent protector. When there is over-voltage, under-voltage and over-current solid barriers in the line, this product can instantly cut off the circuit, avoiding unnecessary damage to electrical equipment. When the circuit returns to normal, the protector can automatically restore the circuit to make the electrical equipment work normally. The overvoltage value, undervoltage value, overcurrent value, circuit recovery time value and overcurrent protection reset time value of this product can be set by themselves. Adjust the corresponding parameters according to local actual conditions and electrical usage conditions.
Technical parameters:
1 Rated voltage: 220VAC 50Hz.
2 Rated current: 1A-63A adjustable (default 40A)
3 Overvoltage action cut-off value: 240V-300VAC can be set (default 270VAC)
4 Overvoltage action cut-off value: 140V-200VAC can be set (default 1 70VAC)
Product features: 1 The product fully conforms to the single-phase self-reclosing recloser produced by the enterprise standard. 2 When the line has overvoltage, undervoltage and overcurrent faults, the product will automatically cut off the line. When the line voltage or current returns to normal, the product will automatically resume normal power supply after the delay time set by the user. No, manual operation is required. 3 When the line appears instantaneous or transient overvoltage, the protector does not malfunction. 4 The line voltage is unstable or the power is suddenly cut off due to some factors, when the power recovers, the product will not connect to the power immediately. This delay time is set by the user according to the local situation. 5 The line voltage should not be higher than 330vac to prevent the product itself from being damaged due to excessive voltage. Please contact the manufacturer if a high power supply is required in a specific situation.
Certificates
Model | ZYB1-63A |
Rated voltage | 220VAC 50Hz. |
Rated current | 1A-63A adjustable (default 40A) |
Overvoltage action cut-off value | 240V-300VAC can be set (default 270VAC) |
Overvoltage action cut-off value | 140V-200VAC can be set (default 170VAC) |
Overcurrent action cut-off value | 63A: 1A-63A can be set (default 40A) / 40A: 1 A-40A can be set |
Transmission delay time after power-on and power-off | 5-300S adjustable (default 5S) |
Boot delay time | 1-300S adjustable (default 5S) |
Reset delay time after overcurrent protection | 30-300s adjustable (default 30s) |
Product overcurrent delay time 6s (overcurrent time greater than this time will be confirmed as overcurrent and provide protection) | |
Own power consumption | less than or equal to 2W |
Electrical machinery life | greater than or equal to 100,000 times |
12 Product dimensions | 66*37*86mm |
Usge:
The multifunctional self-resetting dual display protector integrates over-voltage protection, under-voltage protection, over-current protection and integrated intelligent protector. When there is over-voltage, under-voltage and over-current solid barriers in the line, this product can instantly cut off the circuit, avoiding unnecessary damage to electrical equipment. When the circuit returns to normal, the protector can automatically restore the circuit to make the electrical equipment work normally. The overvoltage value, undervoltage value, overcurrent value, circuit recovery time value and overcurrent protection reset time value of this product can be set by themselves. Adjust the corresponding parameters according to local actual conditions and electrical usage conditions.
Technical parameters:
1 Rated voltage: 220VAC 50Hz.
2 Rated current: 1A-63A adjustable (default 40A)
3 Overvoltage action cut-off value: 240V-300VAC can be set (default 270VAC)
4 Overvoltage action cut-off value: 140V-200VAC can be set (default 1 70VAC)
Product features: 1 The product fully conforms to the single-phase self-reclosing recloser produced by the enterprise standard. 2 When the line has overvoltage, undervoltage and overcurrent faults, the product will automatically cut off the line. When the line voltage or current returns to normal, the product will automatically resume normal power supply after the delay time set by the user. No, manual operation is required. 3 When the line appears instantaneous or transient overvoltage, the protector does not malfunction. 4 The line voltage is unstable or the power is suddenly cut off due to some factors, when the power recovers, the product will not connect to the power immediately. This delay time is set by the user according to the local situation. 5 The line voltage should not be higher than 330vac to prevent the product itself from being damaged due to excessive voltage. Please contact the manufacturer if a high power supply is required in a specific situation.
Certificates
Q: What is the purpose of the Automatic 40A 63A Digital Over Under Voltage Protection Protector?
A: The Automatic 40A 63A Digital Over Under Voltage Protection Protector is designed to protect electrical systems and equipment from both overvoltage and undervoltage conditions. It automatically detects voltage fluctuations and activates protective measures to prevent damage to connected devices.
Q: How does the Automatic 40A 63A Digital Over Under Voltage Protection Protector work?
A: The protector continuously monitors the voltage levels of the electrical supply. If the voltage exceeds or falls below the preset threshold, the protector triggers a response. In the case of overvoltage, it disconnects the power supply to prevent damage. For undervoltage, it restores power once the voltage returns to the acceptable range.
Q: What is the purpose of the Automatic 40A 63A Digital Over Under Voltage Protection Protector?
A: The Automatic 40A 63A Digital Over Under Voltage Protection Protector is designed to protect electrical systems and equipment from both overvoltage and undervoltage conditions. It automatically detects voltage fluctuations and activates protective measures to prevent damage to connected devices.
Q: How does the Automatic 40A 63A Digital Over Under Voltage Protection Protector work?
A: The protector continuously monitors the voltage levels of the electrical supply. If the voltage exceeds or falls below the preset threshold, the protector triggers a response. In the case of overvoltage, it disconnects the power supply to prevent damage. For undervoltage, it restores power once the voltage returns to the acceptable range.